Comparison between BRQPS700-DDTA-C-P, KT-502H1, KT-502H0

Selected Product
BRQPS700-DDTA-C-P

BRQPS700-DDTA-C-P

KT-502H1

KT-502H1

KT-502H0

KT-502H0

Name

BRQPS700-DDTA-C-P

KT-502H1

KT-502H0

Category

Sensing Type

Diffuse reflective type

Sensing Distance

700mm

Sensing Target

Opaque, Translucent material

Light Source

Red LED (660nm)

Response Time

Max. 1ms

1 sec

1 sec

Power Supply

10-30VDC ±10% (ripple P-P: max. 10%)

10.5-45VDC (with backlight LCD)

10.5-45VDC (with backlight LCD)

Current Consumption

Max. 30mA

Sensitivity Adjustment

Sensitivity Adjuster

Operation Mode

Light ON/Dark ON (set by control wire)

Control Output

PNP Open Collector

Connection Type

Connector type(M12)

Environment_Ambient Illumination

Sunlight: Max. 11,000lx, Incandescent lamp: Max. 3,000lx (received illumination)

Environment_Ambient Temperature

-25 to 60℃, storage: -30 to 70℃

-20 to 70 C, storage: 20 to 80 C

-20 to 70 C, storage: 20 to 80 C

Protection Structure

IP67

Environment_Ambient Humidity

35 to 85% RH, storage: 35 to 85% RH

0 to 85%RH, storage: 0 to 85%RH

0 to 85%RH, storage: 0 to 85%RH

Accessories Common

M18 fixing nut: 2, adjustment screwdriver

Weight

Approx. 120g(approx. 25g)

Approx. 1.4kg(approx. 1.2kg)

Approx. 1.4kg(approx. 1.2kg)

Hysteresis (Distance)

Max. 20% at rated sensing distance

Material

Body: Aluminum (AlDc.8S), Cover O-Ring: Buna N

Body: Aluminum (AlDc.8S), Cover O-Ring: Buna N

Display Method

PV display part: 7-segment 5-digit (character size: W4×H8mm), Parameter display part: 14-segment 8-digit (character size: W2.6×H4.8mm), 52-bar meter

PV display part: 7-segment 5-digit (character size: W4×H8mm), Parameter display part: 14-segment 8-digit (character size: W2.6×H4.8mm), 52-bar meter

Display Range

-19999 to 99999

-19999 to 99999

Setting Type

HART-protocol (no setting key)

HART-protocol (no setting key)

Input Type_RTD

DPt100Ω, DPt500Ω, DPt1000Ω, Ni100Ω, Ni500Ω, Ni1000Ω, Cu50Ω, Cu100Ω

DPt100Ω, DPt500Ω, DPt1000Ω, Ni100Ω, Ni500Ω, Ni1000Ω, Cu50Ω, Cu100Ω

Input Type_TC

K, J, T, E, N, S, B, R

K, J, T, E, N, S, B, R

Input Type_Voltage Transmission

-10-75mV, -100-100mV, -100-500mV, -100-2000mV

-10-75mV, -100-100mV, -100-500mV, -100-2000m

Output

DC4-20mA (2-wire)

DC4-20mA (2-wire)

Alarm

Below 3.8mA, Over 20.5mA/Sensor break 3.6mA

Below 3.8mA, Over 20.5mA/Sensor break 3.6mA

Load

Max.(V power supply - 7.5V)/0.22A

Max.(V power supply - 7.5V)/0.22A

Galvanic Insulation

2kVAC (input/output)

2kVAC (input/output)

Explosion Class

Ex d IIC T6

Ex d IIC T6