Comparison between BJX10M-TDT-C, BRQPS700-DDTA-C-P, KT-502H0

Selected Product
BJX10M-TDT-C

BJX10M-TDT-C

BRQPS700-DDTA-C-P

BRQPS700-DDTA-C-P

KT-502H0

KT-502H0

Name

BJX10M-TDT-C

BRQPS700-DDTA-C-P

KT-502H0

Category

Sensing Type

Through-beam type

Diffuse reflective type

Sensing Distance

10m

700mm

Sensing Target

Opaque material of min. 15mm

Opaque, Translucent material

Light Source

Red LED (660nm)

Red LED (660nm)

Response Time

Max. 1ms

Max. 1ms

1 sec

Power Supply

10-30VDC ±10% (ripple P-P: max. 10%)

10-30VDC ±10% (ripple P-P: max. 10%)

10.5-45VDC (with backlight LCD)

Current Consumption

Emitter/Receiver: Max. 20mA

Max. 30mA

Sensitivity Adjustment

Sensitivity Adjuster

Sensitivity Adjuster

Operation Mode

Light ON/Dark ON (set by switch)

Light ON/Dark ON (set by control wire)

Control Output

NPN Open Collector

PNP Open Collector

Connection Type

4mm, 3-wire, 2m (emitter of through-beam type: 4mm, 2-wire, 2m)
(AWG26, core diameter: 0.52mm, number of cores: 20, insulator out diameter: 1mm)

Connector type(M12)

Environment_Ambient Illumination

Sunlight: Max. 11,000lx, Incandescent lamp: Max. 3,000lx (received illumination)

Sunlight: Max. 11,000lx, Incandescent lamp: Max. 3,000lx (received illumination)

Environment_Ambient Temperature

-25 to 60℃, storage: -40 to 70℃

-25 to 60℃, storage: -30 to 70℃

-20 to 70 C, storage: 20 to 80 C

Protection Structure

IP65 (IEC standard)

IP67

Environment_Ambient Humidity

35 to 85% RH, storage: 35 to 85% RH

35 to 85% RH, storage: 35 to 85% RH

0 to 85%RH, storage: 0 to 85%RH

Accessories Common

Mounting bracket, M3 bolt: 4, adjustment screwdriver

M18 fixing nut: 2, adjustment screwdriver

Weight

Approx. 65g (approx. 12g)

Approx. 120g(approx. 25g)

Approx. 1.4kg(approx. 1.2kg)

Hysteresis (Distance)

Max. 20% at rated sensing distance

Material

Body: Aluminum (AlDc.8S), Cover O-Ring: Buna N

Display Method

PV display part: 7-segment 5-digit (character size: W4×H8mm), Parameter display part: 14-segment 8-digit (character size: W2.6×H4.8mm), 52-bar meter

Display Range

-19999 to 99999

Setting Type

HART-protocol (no setting key)

Input Type_RTD

DPt100Ω, DPt500Ω, DPt1000Ω, Ni100Ω, Ni500Ω, Ni1000Ω, Cu50Ω, Cu100Ω

Input Type_TC

K, J, T, E, N, S, B, R

Input Type_Voltage Transmission

-10-75mV, -100-100mV, -100-500mV, -100-2000m

Output

DC4-20mA (2-wire)

Alarm

Below 3.8mA, Over 20.5mA/Sensor break 3.6mA

Load

Max.(V power supply - 7.5V)/0.22A

Galvanic Insulation

2kVAC (input/output)

Explosion Class

Ex d IIC T6